183
MN F09 002 US  DOK-383E  Issue/Rev. 3.65 (02/24)
MultiFlow  Configuration of the MultiFlow
No.
Name
Seal
K
Factory
Setting
Meaning
3.1.6.9
Sensor interface
3.1.6.9.1
Use SI
S/M
2
0 (no)
Activation of the optional sensor module
3.1.6.9.2
SI node
S/M
2
0
Node number of sensor module when activated.
3.1.6.9.3
Compartment number
S/M
2
1
Number of compartments to monitor.
(1 .. 20)
3.1.6.9.4
Request interval
2
60s
Average request interval without connecting external
power supply.
(0 .. 21600s)
3.1.6.9.5
Transmission delay
S/M
2
50ms
Interface-end telegram delay on CAN bus. (0 ..
255ms)
3.1.6.9.6
Trigger interval
S/M
2
5s
Interval before watchdog is triggered (inactivity
detection). (0 .. 60)
Use SI
This parameter is used to activate the sensor interface support. If this
parameter is set to '0' there is no sensor interface control.
SI node
The CAN bus node numbers via which the sensor interface can be
addressed.
Compartment number
Number of compartments on the vehicle. Used to define the number of
group sensors to be used.
Request interval
This parameter determines the intervals at which the sensors should be
monitored by the sensor interface in offline mode. This is an average
value. The precise monitoring interval varies for safety reasons to
different degrees above and below the specified value.
Transmission delay
Adjustable transmission delay of the sensor interface when transferring
several CAN telegrams. You should always consult the manufacturer
before changing this parameter.
Trigger interval
Determines the interval for inactivity monitoring of the sensor interface.
Special CAN telegrams must be sent to the sensor interface within this
period in order to continue to operate in online mode. If there are several
“communication-friendly” devices connected to the CAN bus you can
increase the trigger interval for the sensor interface.