MultiFlow Configuration of the MultiFlow
•
Sensor type
There are 4 different sensor types to choose from:
1.
Digital NC contact
2.
Digital NO contact
3.
Namur NC contact
4.
Namur NO contact
•
Alarm event
Using this menu item specify whether, in the event of a detected change
of a sensor input in addition to the entries generated in the logbook and
the event section of the start screen the output of a user-acknowledged
alarm message to the MultiFlow display is required.
9.13.4
Sensor monitor
Connecting the sensor module allows the functions of the MultiFlow to be
enhanced by a rudimentary sensor monitor.
Can only be selected when the connection to the
sensor interface is active.
(De) activates the sensor monitor. Time and (where
available) GPS position are saved. Monitor remains
active until a sensor status change with an activated
alarm message is detected.
Display of current monitor status
Printout of the sensor monitor status report
All available sensor monitor parameters are compiled under menu item
4.8. The 4.8.1 “Activation” menu item is used to (de)activate the sensor
monitor. This parameter is protected by the master password. The date
and time are saved when the monitor is (de)activated. The current GPS
coordinates are also saved if the MultiFlow is connected to a GPS-
compatible EMIS via the CAN bus.
The current status of the sensor monitor can be checked using parameter
4.8.2. As well as the current monitoring status, it shows the status of the
connection to the sensor interface, the time and date and the GPS data
(if available) at the time of the (de)activation. You can also use the F1 key
to request a status report to be sent to the printer. See also chapter 11.10
"Sensor monitor status report " / page 238.