190
Sening® is a registered trademark of FMC Technologies
MN F09 002 US  DOK-383E  Issue/Rev. 3.65 (02/24)
MultiFlow  Configuration of the MultiFlow
The additional hose paths must be entered in the hose approval.
Abbreviations '1'..'8' apply here. '1' indicates in this case that the hose
path associated with the external output 1 should be used for delivery.
Parameters for the additional hose path specification are subject to
calibration protection. To change the parameters, the electronic seal
must be broken.
9.14.1.3
Idle operation
If the IO interface is operated without an active link and without
assignment of an additional hose routing, the MultiFlow only monitors the
two inputs (IN1 and IN2). Modifications to the inputs are displayed on the
Info area of the MultiFlow homepage screen and are also recorded in the
logbook. In cases where the MultiFlow unit is operated with a GPS-
capable EMIS, the corresponding location details are also recorded in the
logbook.
Start screen
F.A .S en in g Mu lt iFl ow
S el ec t pr od uc t a nd
vo lu me wi th <S TAR T>
Pr in t re po rt s
wi th <P RIN T>
Cu st om iz e se tt ing s
wi th <F 3>
R ea dy
I O on li ne
I O In pu t 2: 1
I O In pu t 2: 0
Sea l Lo ad M enu
9.14.2 Configuration of the device
9.14.2.1
IO Interface
The IO interface is configured via its DIP switches.