MultiFlow  Configuration of the MultiFlow
Use hose path
It is possible to specify a further hose path. This parameter is used to
determine that the related output should be used to select an
additional hose path. This hose path must be added to the hose
approval (parameter 3.1.8.7). Once done, it is displayed in the hose
path selection before a delivery.
Hose path designation
The user can specify any name for the unique identification of the
additional hose path. The same name cannot be used for different
pre-settings.
The additional hose path must
be added to the hose approval
(parameter 3.1.8.7) to enable it
to be displayed in the hose
path selection options at the
start of delivery. When using
the IO module the existing
abbreviations for the hose
approval are extended by the
abbreviations "1 .. 8".
These indicate respectively the
external output which should be
used to control the additional
hose path. '8' means in this
case that the hose path
associated with the external
output 8 should be enabled.
Sel ec ti on : 31 60 482 2
Des ig na ti on
Ho se pa th 8
Te xt
Co nf ir m en tr y
b y pr es si ng <P R IN T>
Di sc ar d en tr y
b y pr es si ng <ST OP >
New De l = =>
Sel ec ti on
Hos e ap pr ov al
> U VP SB 8 <
Ava il ab le h os es
S m al l De l - --