MN F09 002 US  DOK-383E  Issue/Rev. 3.62
(02/13)
MultiFlow  Form Description
206
Sening® is a registered trademark of FMC Technologies
ID
Output
Name
Remarks
60
At the drop temperature
or, if compensated
volume at nn ºC
Delivery mode (long)
61
nnnnnnnn L
Total Start VT
Totalizer Reading for VT before
start of the first discharge
62
nnnnnnnn L
Total Start V0
Totalizer Reading for V0
before start of the first discharge
63
nnnnnnnn Kg
Total Start Mass
Totalizer Reading for Mass before
start of the first discharge
64
nnnnnnnn L
Total Start Add
Totalizer Reading for Additive
before start of the first discharge
65
nnnnnnnn L
Total End VT
Totalizer Reading for VT after the
last discharge
66
nnnnnnnn L
Total End V0
Totalizer Reading for V0 after the
last discharge
67
nnnnnnnn Kg
Total End Mass
Totalizer Reading for Mass
after the last discharge
68
nnnnnnnn L
Total End Add
Totalizer Reading for Additive
after the last discharge
69
Total ex. VAT 12345.67 EUR
Total ex VAT
Net total price of discharge
70
VAT 12.34% 1234.56 12345.67 EUR
Rate of tax
Total tax for discharge
71
Total incl. VAT 12345.67 EUR
Total with VAT
Gross total price for discharge
72
With exchange rate 1.23456
With exchange rate
Exchange rate
73
Total gross 12345.67 DM
Total gross
Gross total price for discharge in
second currency
Elements marked by an (*) are subject to W & M regulations. When
saving the layout and before each delivery a test is made of whether the
necessary elements are contained in the form (see parameter 3.1.5.4,
minimal layout).
Elements marked with (
**
) are only used with certain software features.
If forms are used which have the required text printed in, the element "26"
may be omitted.
10.1.3.2
Placeholders
Placeholders are provided for values which are only produced during the
printout (e.g. time, date, discharged amount). The placeholders are set
between '#' characters and the figure indicates the number of characters
reserved for formatting.
For example, six characters ( #6# ) are provided for the meter number.
The delivery date can be regarded as a special case. Eight characters
are sufficient for the short form without the century figure. However, if the
century is to be printed, then a placeholder for minimum 10 characters
must be provided.