MultiFlow Printing out Reports
11.7.1 Log Book
In the log book all activities on the device (in particular discharges) are
logged. From this log the trip reports are generated.
The log book (list of events) is designed as a ring buffer in which only a
limited number of events can be retained (approx. 100 receipts).
For data security the event data are protected with a checksum.
The following events are retained in the log book:
PowerUP
Emergency receipt
• Switching on the device
• Producing an emergency receipt
E.g.:
C'5338.546360'N'953.363720'E
'
26.50'4'1.2
• GPS coordinates
• Status: C: current coordinates, L: last valid
coordinates, N: N/A
• Latitude
• Hemisphere latitude
• Longitude
• Hemisphere longitude
• Height
• Number of satellites
• Position error
• The system can supply GPS data, but no data is
available at the moment.
Information about office communication
• Logon: Switching on, initialization, driver registration.
Driver log-in. If driver log-in is deactivated at the star
up of MultiFlow (parameter 31451) then driver no. 1 i
entered.
• 000001Driver number (menu 36x1)
• Driver Driver name (menu 36x2)
• Driver Access level (driver or master)
• Error: An error has occurred
• No link to #2
No link to the CAN bus member with the node numb
2 can be established.
• Level Timeout
Within the transmission interval for the radio delivery
safety (parameter 31651) no signals have been
received. Might be caused by radio interference etc.
• Deadman Timeout
Within the transmission interval for the dead man
switch (parameter 31662) no signals have been
received. Might be caused by radio interference etc.
Information about external IO module
External IO module connected and ready for
operation.
Interrupted CAN communication.
Reset detected in online mode.