Sening
®
is a registered trademark of FMC Technologies
249
MN F09 002 US  DOK-383E  Issue/Rev. 3.65 (02/24)
MultiFlow  Error messages and status information
Message
Meaning
P
P
l
l
e
e
a
a
s
s
e
e
d
d
r
r
a
a
i
i
n
n
t
t
h
h
e
e
M
M
e
e
t
t
e
e
r
r
!
!
51
If residual discharge has not been carried out the driver must
press the <F2> key. A corresponding entry is then made in the
logbook and this message is displayed:
The MultiFlow remains in this operating state until it is switched
off, i.e. it will not react to key entries (e.g. <START>, <STOP>
etc.) (only if parameter 31851 is activated).
NOTE: Restart the MultiFlow by switching it OFF and
then ON again.
P
P
r
r
i
i
c
c
e
e
p
p
r
r
e
e
s
s
e
e
t
t
i
i
l
l
l
l
e
e
g
g
a
a
l
l
!
!
52
The price entered lies outside the range allowed. (0…999999)
P
P
r
r
i
i
n
n
t
t
R
R
e
e
c
c
e
e
i
i
p
p
t
t
?
?
53
After a successful discharge an invoice selection can be printed
out with <F1> or a delivery note selection with <F2>. Depending
on the setting of parameter 3.1.4.0.1 the invoice setting can be
suppressed. In this case a delivery note is printed without query.
P
P
r
r
i
i
n
n
t
t
I
I
n
n
v
v
o
o
i
i
c
c
e
e
o
o
r
r
D
D
e
e
l
l
i
i
v
v
e
e
r
r
y
y
N
N
o
o
t
t
e
e
?
?
54
At the end of the discharge a receipt can be printed in the form of
an invoice or a delivery note. A selection can be made between
the printout of an invoice (<F1>) or a delivery note (<F2>).
Depending on the setting of parameter 3.1.4.0.1 the invoice
setting can be suppressed. In this case a delivery note is printed
without query (see chapter 6.6 "Printing Delivery Notes and
Invoices" / page 81).
P
P
r
r
i
i
n
n
t
t
e
e
r
r
e
e
r
r
r
r
o
o
r
r
!
!
I
I
n
n
c
c
o
o
r
r
r
r
e
e
c
c
t
t
r
r
e
e
s
s
p
p
o
o
n
n
s
s
e
e
t
t
o
o
F
F
D
D
W
W
p
p
r
r
o
o
t
t
o
o
c
c
o
o
l
l
55
The printout of information relevant to W & M regulations on the
receipts occurs in the FDW mode which ensures correct output.
The error message indicates an error in the printer control.
If the problem persists after repeated attempts, the receipt data
must be copied manually from the display.
IMPORTANT: Service personnel must be consulted
immediately.
P
P
r
r
i
i
n
n
t
t
e
e
r
r
d
d
o
o
e
e
s
s
n
n
o
o
t
t
r
r
e
e
s
s
p
p
o
o
n
n
d
d
!
!
56
Message appears if the long distance transfer protocol (parameter
3161) is switched off and should be printed.
Cause: The printer status cannot be determined by the
software! Printer probably switched off.
P
P
r
r
o
o
d
d
u
u
c
c
t
t
c
c
h
h
a
a
n
n
g
g
e
e
d
d
!
!
W
W
a
a
s
s
t
t
h
h
e
e
M
M
e
e
t
t
e
e
r
r
d
d
r
r
a
a
i
i
n
n
e
e
d
d
?
?
57
When using the "device for emptying and refilling the measuring
system" according to authorization 5.162 / 01.01, the operator is
asked during a product change whether the necessary emptying /
refilling has been carried out (only if parameter 31851 is
activated).
NOTE: See chapter 6 "Discharge" / page 71
P
P
r
r
o
o
d
d
u
u
c
c
t
t
c
c
h
h
a
a
n
n
g
g
e
e
d
d
!
!
D
D
r
r
a
a
i
i
n
n
t
t
h
h
e
e
M
M
e
e
t
t
e
e
r
r
?
?
58
The metering system residual discharge message can be
switched on and off with parameter 31851.
P
P
r
r
o
o
d
d
u
u
c
c
t
t
S
S
e
e
l
l
e
e
c
c
t
t
i
i
o
o
n
n
i
i
l
l
l
l
e
e
g
g
a
a
l
l
!
!
59
Message appears if, after a discharge, further products should be
delivered, but the maximum number of metered liquid products
(parameter 3152) has already been reached!
P
P
u
u
l
l
s
s
e
e
E
E
r
r
r
r
o
o
r
r
!
!
60
The maximum permissible number of disturbance/error pulses
has been reached.
The delivery is interrupted and a receipt must be printed
(parameter 3313).
P
P
u
u
l
l
s
s
e
e
s
s
e
e
n
n
s
s
o
o
r
r
d
d
e
e
f
f
e
e
c
c
t
t
i
i
v
v
e
e
!
!
61
The MultiFlow has detected a functional fault on the pulse
transmitter.
The delivery is interrupted and a receipt must be printed.
R
R
e
e
m
m
o
o
t
t
e
e
-
-
M
M
o
o
d
d
e
e
!
!
M
M
a
a
n
n
u
u
a
a
l
l
O
O
p
p
e
e
r
r
a
a
t
t
i
i
o
o
n
n
n
n
o
o
t
t
a
a
l
l
l
l
o
o
w
w
e
e
d
d
!
!
62
Mode of operation is set to remote operation. (parameter 3141)
NOTE: Reset only possible via IMC or EMIS.
R
R
e
e
s
s
u
u
m
m
e
e
D
D
e
e
l
l
i
i
v
v
e
e
r
r
y
y
?
?
63
During the discharge the pre-selected quantity entered has been
reached and the discharge stopped. If the discharge should be
continued (press <F1> for "YES") the additional quantity to be
delivered must then be entered. Should the discharge not be
continued, press <F2> for "NO".
R
R
e
e
s
s
u
u
m
m
e
e
w
w
i
i
t
t
h
h
S
S
T
T
A
A
R
R
T
T
B
B
r
r
e
e
a
a
k
k
w
w
i
i
t
t
h
h
S
S
T
T
O
O
P
P
A
A
d
d
d
d
i
i
t
t
i
i
o
o
n
n
.
.
P
P
r
r
e
e
s
s
e
e
t
t
F
F
1
1
64
A discharge that is underway has been interrupted and the pre-
selected quantity entered has not yet been reached. With <Stop>
the process can be interrupted, or with <F1> an additional
quantity can be delivered.

Table of Contents

Related product manuals