EasyManua.ls Logo

TechnipFMC Sening MultiFlow - Page 309

TechnipFMC Sening MultiFlow
356 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
MN F09 002 US  DOK-383E  Issue/Rev. 3.65 (02/24)
MultiFlow  Address and contact details
Sening
®
is a registered trademark of FMC Technologies
311
No.
Name
Seal
K
Factory
Setting
Meaning
3.5.n.n.6.1.1
Scale price 1
M
3
0
Price setting for delivery quantity from 0 upwards.
3.5.n.n.6.1.2
Scale price 2
M
3
0
Price setting for user defined delivery quantity.
3.5.n.n.6.1.3
Scale price 3
M
3
0
Price setting for user defined delivery quantity.
3.5.n.n.6.1.4
Scale price 4
M
3
0
Price setting for user defined delivery quantity.
3.5.n.n.6.1.5
Scale price 5
M
3
0
Price setting for user defined delivery quantity.
3.5.nn.6.2
Price factor
M
3
The standard price applies to 1, 10, 100 units, etc.
Price factor "0" defines a fixed price which is not
dependent on quantity (packed goods only).
3.5.nn.6.3
Tax rate
M
3
Entry of rate for value added tax (percent).
3.5.n.n.6.4
CO2 Costs
M
3
Definition according to German CO2 Cost
Allocation law
3.5.n.n.6.4.1
Enable
M
3
1
General (de)activation of optional info on the
receipt
3.5.n.n.6.4.2
Caloric value
M
3
42,8 GJ/t 1)
Calorific value in [GJ/t]
3.5.n.n.6.4.3
Emission factor
M
3
0,074 CO2/GJ
1)
Calorific value-related emission factor in [tCO2/GJ]
3.5.n.n.6.4.4
Certificat costs
M
3
30 1)
Price per emission certificate
3.5.n.n.6.4.5
CO2CostInfo
M
3
1 1)
(De)Activation of the reference to the
reimbursement claims regulated in Section 6 §2
and Section 8 §2.
3.5.nn.7
Temp.
compensation
3.5.nn.7.1
Compensation
Cal.
1
1 (yes)
Activation of compensation:
1. No:
Compensation deactivated.
Printout carried out with VT.
2: Yes (receipt: V0&VT):
VT and V15 printout carried out using form
module 12.
(Use for products with voluntary compensation.)
3: Yes (receipt: V0):
V0 printout carried out using form module 12.
(Use for products with statutory compensation.)
3.5.nn.7.2
Comp. temperature
Cal.
1
15°C
Selection of compensation temperature
3.5.nn.7.3
Product group
Cal.
1
Determination of the compensation algorithm in
dependence of the product group:
1 Packed Goods
2 Crude Oil (API-Table 54A)
3 Refined Oil (API-Table 54B)
4 Special Product (API Table 54X)
for liquid gas & bitumen
5 Lube Oil (API-Table 54D)
6 Direct-Linear (Mixed Products)
for e.g. E5, E10
3.5.nn.7.4
Mean density
Cal.
1
Physical constant specified by W&M.
3.5.nn.7.5
Meter Factors
3.5.nn.7.5.1
Meter Factor 1
Cal.
1
See "Fehler! Verweisquelle konnte nicht gefunden
werden."
3.5.nn.7.5.2
Meter Factor 2
Cal.
1
See "Fehler! Verweisquelle konnte nicht gefunden
werden."
3.5.nn.7.5.3
Meter Factor 3
Cal.
1
See "Fehler! Verweisquelle konnte nicht gefunden
werden."
3.5.nn.7.5.4
Meter Factor 4
Cal.
1
See "Fehler! Verweisquelle konnte nicht gefunden
werden."
3.5.nn.7.5.5
Flow Rate 1
Cal.
1
Upper limit of validity range for Meter Factor 1
3.5.nn.7.5.6
Flow Rate 2
Cal.
1
Upper limit of validity range for Meter Factor 2
3.5.nn.7.5.7
Flow Rate 3
Cal.
1
Upper limit of validity range for Meter Factor 3
3.5.nn.7.5.8
Flow Rate 4
Cal.
1
Upper limit of validity range for Meter Factor 4
3.5.nn.7.5.9
Copying from ...
Cal.
1
Copies the calibration data (see above) from a
different product register.
3.5.n.n.7.6
Min. product temp.
Cal.
1
99
Autom. end of delivery in the event of temperature
shortfall. Applicable range -20°C to 20°C. The value
99 deactivates this function.
3.5.nn.7.7
Change factor
Required for product group "6 Direct-Linear" to
temperature volume compensation of mixed products
(E5, E10 ...)
3.5.nn.7.7.1
Min. temperature
Cal.
1
-20
Min. temperature for temperature volume
compensation -120 .. 120°C

Table of Contents

Related product manuals