Crosspatch Setup Window
Beep Dly Field
The Beep Dly (Delay) field identifies the amount of time, in ms, between the digit string detection and status beeps echoed
back to the hand-held radio.
The range for this field is 0 to 5000ms.
Patch Timeout Field
The Patch Timeout field identifies the amount of time, in seconds, allowed for inactivity on an active patch. If a patch is
inactive for the specified period of time, the patch is dropped.
The range for this field is 0 to 999 seconds.
NOTE: Patch Timeout must be greater than Global Timeout.
Global Field
The Global field identifies the amount of time, in seconds, allowed for any patch.
The range for this field is 0 to 32000 seconds.
Drop All Field
The Drop All field identifies the DTMF digit sequence used to drop all current patches. The number entered must be the
number of digits specified in the Dialing Digits field.
The range for this field is 0 to 9999 seconds.
RCP Tables
The required fields depend on the mode selected:
XPATCH - Requires #1 or #2, IP Address, Add String and Delete String.
DIAL - Requires Phone, Add String and Delete String.
DLVOIP - Requires Rx Multicast/Port, TX Multicast/Port, Add String and Delete String.
PHONEP - Requires Add String and Delete String.
LPTCH - Requires Add String and Delete String.