Setup Information
80
Group Digit Field - Local and Tone Modes
The Group Digit field identifies the group digit. The group digit is a wild card that can represent any digit. Placing a group
digit within a filter allows any digit appearing at that location in the tone string to pass through the filter.
The range for this field is 0–9 or A–F.
The default for this field is A.
Repeat Digit Field - Local and Tone Modes
The Repeat Digit field identifies the digit that separates two (2) digits sent back to back. On occasion, radio system messages
require two (2) of the same digits to be entered back to back. Use of repeat digits delimits tone duration ensuing continuous
transitions.
The range for this field is B–F.
The default for this field is E.
ANI Decoder # Field
The ANI Decoder # field lists, in sequential order, the available ANI Decoders.
ANI Call Type Drop Down Menu - Local, Tone, and Console Modes
The ANI Call Type drop down menu, shown in Figure 38, identifies the type of call for the ANI Decoder #.
Available selections for this field are: Emergency, Group, Individual, or Status.
FIGURE 38. ANI Call Type Drop Down Menu—Per Line Setup