Function Tone Duration Field
The Function Tone Duration field identifies the duration, in ms, of the function tone. When dual function tones are set, both
tones are set to this duration.
The range for this field is 0 to 999ms.
In most cases, this value is set to 40ms.
Function Tone Magnitude Field
The Function Tone Magnitude field identifies the level, in dBm, of the function tone.
The range for this field is -60 to 12dB.
FTone 1-16 Frequency Fields
The FTone 1-16 Frequency fields identify the value, in Hz, associated with each function tone burst. The standard function
tones and their frequencies are shown in Table 14.
NOTE: If the second value is set at 0, no second function tone is sent.
The range for this field is 0 to 3200 Hz.
Function Tone
TABLE 14. Standard Function Tone Frequencies
Function Tone
Number
Frequency
(Hz)
Function Tone
Number
Frequency
(Hz)
F1 1950 F9 1150
F2 1850 F10 1050
F3 1750 F11 950
F4 1650 F12 850
F5 1550 F13 750
F6 1450 F14 650
F7 1350 F15 550
F8 1250 F16 450