5.3 Reference Guide using RS-232C commands
112
CONF:RFTC:PD:DATA_LEN <Value>
Description
This command writes length of payload’s data.
Value
data length : 0 ~ 339, 0(default-longest supported length)
READ:RFTC:PD:TEST_MODE?
Description
This command reads test mode.
CONF:RFTC:PD:TEST_MODE <Value>
Description
This command writes test mode.
Value
Test mode : LOOPBACK_TEST, TRANSMITTER_TEST(default), NULL_PKT_TEST
READ:RFTC:PD:P_DEN?
Description
This command reads maximum value of the power density per 100kHz EIRP.
READ:RFTC:PD:F_MAX?
Description
This command reads center frequency at which the power density reached the maximum value.
5.3.6 Power Control(PC)
EXEC:RFTC:PC:RUN
Description
This command executes measurement of the minimum RF output power and the step of power controlled by
the DUT at the given TX frequency. This can be used for power control test case(TRM/CA/03/C).
EXEC:RFTC:PC:STOP
Description
This command stops execution of power control measurement.
READ:RFTC:PC:CH?
Description
This command reads RX frequency of a tester(TX for a DUT).
CONF:RFTC:PC:CH <Value>
Description
This command writes RX frequency of a tester(TX for a DUT).
Value
channel : RX frequency of a tester (TX for a DUT), 0 ~ 78, 0-39-78(default)
READ:RFTC:PC:PACK_TYPE?
Description
This command reads packet type.
CONF:RFTC:PC:PACK_TYPE <Value>
Description
This command writes packet type.