Appendix B. RF Test Cases of the TC-3000C
214
supports power control, then the tester will consecutively send LMP_incr_power_req
requests until the LMP_max_power response would be received from the DUT. The time
delay between two consequential LMP_incr_power_req requests depends on the
Pow.SetTime parameter (to modify the value use: Menu Configuration DUT
More3/5 Pow.SetTime, default value is equal to 1 second).
4. For the given channel frequency the tester records output power of the DUT from the start
to the end of a packet. Tester records the highest and the lowest power value in the trace
and calculates average power from 20% to 80% of the trace. The path losses value is
added to the results. To set the path losses value, use: Menu Configuration DUT
More1/5 PathLoss. This step is repeating for specified number of packets (see the
“Number of packets” parameter) and for each frequency channel. If the frequency channel is
changed and the hoping mode is the single frequency mode, the tester sets new
parameters of the test mode using LMP_test_control command.
Test Results
Pav is the average RF-output power of the DUT for given frequency channel, measured in
dBm.
Pmax is the maximum peak RF-output power of the DUT for given frequency channel,
measured in dBm.
Pmin is the minimum RF-output power of the DUT for given frequency channel, measured in
dBm. The result has only informative character and is not used to reach a verdict.
To reach a verdict the test results are compared with the limit parameters:
“Upper Limit of average power”
“Lower Limit of average power”
“Upper Limit of peak power”
To change the parameters, use the Edit menu of the test case. If the flag “Use Default” is
selected then all of displayed values of parameters are ignored and the values according to RF
Test Specification [1] are assigned automatically.
Requirement to Initial Condition of a DUT
If the DUT can be controlled through HCI, the DUT must be connected to an appropriate HCI
port of the tester and correct value of the HCI Port parameter must be specified in DUT
configuration (Menu Configuration DUT More1/5 HCIPort).
If the DUT does not have HCI then the DUT must be in the Inquiry Scan/Page Scan state
(maximum activity of the scan mode is desirable) and Test Mode should be enabled (for
Transmitter Test and Loop back Test Modes).
5.2.2 Power Density (TRM/CA/02/C)
Goal
Verification of the maximum RF-output power density
Parameters
1. Test mode: Transmitter test, Loop back, Null packets (simple connection).
2. Data length parameter specifies which length of the packet’s payload will be used for the
test case. If the parameter is equal to 0 then the tester will read LMP features of the DUT