5.3 Reference Guide using RS-232C commands
130
READ:RFTC:BERFER:BER?
Description
This command reads bit error rate from BER & FER test
Returned Value
The measurement returns BER values of each channel established in accordance with the sequence
and quantities.
A delimiter “ ,” is used to separate the measured values over the channels set.
nan: This value returns when no effective measurement value exists or no packet is received.
READ:RFTC:BERFER:PER?
Description
This command reads packet error rate from BER & FER test.
Returned Value
The measurement returns PER values of each channel established in accordance with the sequence
and quantities.
A delimiter “ ,” is used to separate the measured values over the channels set.
nan: This value returns when no effective measurement value exists or no packet is received.
5.3.19 EDR Relative Transmitter Power(ETP)
EXEC:RFTC:ETP:RUN
Description
This command executes EDR Relative Transmit Power(TRM/CA/10/C)
EXEC:RFTC:ETP:STOP
Description
This command stops execution of running EDR Relative Transmit Power(TRM/CA/10/C) measurement. It is
used to cancel the running RF test case which is started by “EXE:RFTC:ETP:RUN” command.
READ:RFTC:ETP:CH?
Description
This command reads channl value for EDR Relative Transmit Power(TRM/CA/10/C) measurement
CONF:RFTC:ETP:CH <Value>
Description
This command sets channel for EDR Relative Transmit Power(TRM/CA/10/C) measurement.
Value
channel : 0-39-78(default)
(ex) In case of setting channel 0 : CONF:RFTC:ETP:CH 0
In case of setting channel0, 39, 78 : CONF:RFTC:ETP:CH 0-39-78
READ:RFTC:ETP:PACK_TYPE?
Description
This command reads packet type for EDR Relative Transmit Power(TRM/CA/10/C) measurement
CONF:RFTC:ETP:PACK_TYPE <Value>
Description
This command sets packet type for EDR Relative Transmit Power(TRM/CA/10/C) measurement.
Value