5.3 Reference Guide using RS-232C commands
136
READ:RFTC:EDPE:PACK_NUM?
Description
This command reads number of packet for EDR Differential Phase Encoding(TRM/CA/12/C) measurement.
CONF:RFTC:EDPE:PACK_NUM <Value>
Description
This command sets number of packet for EDR Differential Phase Encoding(TRM/CA/12/C) measurement
Value
Number of packets : 0~65535, 100(default)
READ:RFTC:EDPE:HOP?
Description
This command reads hopping mode for EDR Differential Phase Encoding(TRM/CA/12/C) measurement.
CONF:RFTC:EDPE:HOP <Value>
Description
This command sets hopping mode for EDR differential phase encoding(TRM/CA/12/C) measurement.
value
Hopping Mode : OFF(default), ON
READ:RFTC:EDPE:BER?
Description
This command reads BER value for EDR Differential Phase Encoding(TRM/CA/12/C) measurement. Before
reading this value using “READ:RFTC:EDPE:BER?” command, RF test case should be executed to update
this value by sending “EXEC:RFTC:EDPE:RUN”.
READ:RFTC:EDPE:PER?
Description
This command reads PER value for EDR Differential Phase Encoding(TRM/CA/12/C) measurement. Before
reading this value use “READ:RFTC:EDPE:PER? Command, RF test case should be executed to update
this value by sending “EXEC:RFTC:EDPE:RUN”.
5.3.22 EDR In-band Spurious Emission(ETP)
EXEC:RFTC:ESE:RUN
Description
This command executes EDR In-band Spurius Emission(TRM/CA/13/C) measurement.
EXEC:RFTC:ESE:STOP
Description
This command stops execution of EDR In-band Spurious Emission(TRM/CA/13/C) measurement. It is used
to cancel the running RF test case which is started by “EXE:RFTC:ESE:RUN” command.
READ:RFTC:ESE:CH?
Description
This command reads channel value for EDR In-band Spurious Emission(TRM/CA/13/C) measurement.
CONF:RFTC:ESE:CH <value>
Description
This command sets channel for EDR In-band Spurious Emission(TRM/CA/13/C) measurement.
value