5.3 Reference Guide using RS-232C commands
115
5.3.8 Frequency Range(FR)
EXEC:RFTC:FR:RUN
Description
This command executes measurement of lowest and highest frequencies below and above the operating
frequencies at which spectral power density drops below the level of 80dBm/Hz e.i.r.p(-30 dBm if measured
in a 100 kHz bandwidth). This can be used for the frequency range test case(TRM/CA/04/C).
EXEC:RFTC:FR:STOP
Description
This command stops execution of frequency range measurement.
READ:RFTC:FR:DATA_LEN?
Description
This command reads length of payload’s data of frequency range.
CONF:RFTC:FR:DATA_LEN <Value>
Description
This command writes length of payload’s data.
Value
length of payload’s data : 0 ~ 339, 1(default)
READ:RFTC:FR:SWP_NUM?
Description
This command reads number of sweeps.
CONF:RFTC:FR:SWP_NUM <Value>
Description
This command wirtes number of sweeps.
Value
Number of sweeps : 1 ~ 65535, 1(default)
READ:RFTC:FR:TEST_MODE?
Description
This command reads test mode.
CONF:RFTC:FR:TEST_MODE
Description
This command writes test mode.
Value
Test mode : LOOPBACK_TEST, TRANSMITTER_TEST(default), NULL_PKT_TEST
READ:RFTC:FR:F_L?
Description
This command reads lowest frequency below the operating frequencies at which spectral power density
drops below the level of 80 dBm/Hz e.i.r.p(-30 dBm if measured in a 100kHz bandwidth)
READ:RFTC:FR:F_H?
Description
This command reads highest frequency above the operating frequencies at which spectral power density
drops below the level of 80 dBm/Hz e.i.r.p(-30 dBm if measured in a 100kHz bandwidth)