5.3 Reference Guide using RS-232C commands
129
channel : RX frequency of a tester (TX for a DUT), 0 ~ 78, 0-39-78(default)
READ:RFTC:BERFER:PACK_TYPE?
Description
This command reads packet type.
CONF:RFTC:BERFER:PACK_TYPE <Value>
Description
This command writes packet type.
Value
packet type : DH3, DH5(default)
READ:RFTC:BERFER:HOP?
Description
This command reads hopping mode.
CONF:RFTC:BERFER:HOP <Value>
Description
This command writes hopping mode.
Value
hopping mode : ON, OFF(default)
READ:RFTC:BERFER:RX_LEV?
Description
This command reads power at the receiver input of the DUT in dBm.
CONF:RFTC:BERFER:RX_LEV <Value>
Description
This command writes RX power at the receiver input of the DUT in dBm.
Value
DUT RX Level : -327.68 ~ 20
READ:RFTC:BERFER:BYTES?
Description
This command reads minimum number of packets to measure BER & FER.
CONF:RFTC:BERFER:BYTES <Value>
Description
This command writes minimum number of packets to measure BER & FER.
Value
minimum number of samples : 0 ~ 2147000000, 500(default)
READ:RFTC:BERFER:DIRTY_TX?
Description
This command reads dirty transmitter mode.
CONF:RFTC:BERFER:DIRTY_TX <Value>
Description
This command writes dirty transmitter mode.
Value
dirty transmitter mode : ON(default), OFF