5.3 Reference Guide using RS-232C commands
141
EXEC:RFTC:EML:STOP
Description
This command stops execution of running EDR Maximum Input Level(RCV/CA/10/C) measurement. It is
used to cancel the running RF test case which is started by “EXE:RFTC:EML:RUN” command.
READ:RFTC:EML:CH?
Description
This command reads setting channel for EDR Maxmim Input Level(RCV/CA/10/C) measurement.
CONF:RFTC:EML:CH <Value>
Description
This command sets channel for EDR Maximum Input Level(RCV/CA.10) measurement.
Value
channel : 0-39-78(default)
(예) In case of setting channel 0 : CONF:RFTC:EML:CH 0
In case of setting channel 0, 39, 78 : CONF:RFTC:EML:CH 0-39-78
READ:RFTC:EML:PACK_TYPE?
Description
This command reads packet type fro EDR Maximum Input Level(RCV/CA/10/C) measurement.
CONF:RFTC:EML:PACK_TYPE <Value>
Description
This command sets packet type for EDR Maximum Input Level(RCV/CA/10/C) measurement
Value
Packet type : 2-LONGEST(default),3-LONGEST,2-DH1,3-DH1,2-DH3,3-DH3,2-DH5,3-DH5,2-EV3,3-EV3,2-
EV5,3-2V5
READ:RFTC:EML:HOP?
Description
This command reads hopping mode for EDR Maximum Input Level(RCV/CA/10/C) measurement.
CONF:RFTC:EML:HOP <Value>
Description
This command sets hopping mode for EDR Maximum Input Level(CV/CA/10/C) measurement.
Value
Hopping Mode : OFF(default), ON
READ:RFTC:EML:RX_LEV?
Description
This command reads DUT RX Level value for EDR Maximum Input Level(RCV/CA/10/C) measurement.
CONF:RFTC:EML:RX_LEV <Value>
Description
This command sets DUT RX Level for EDR Maximum Input Level(RCV/CA/10/C) measurement.
Value
DUT RX Level : -327~20, -20(default)
READ:RFTC:EML:BYTES?
Description
This command reads number of received byte for EDR Masimum Input Level(RCV/CA/10/C) measurement.