Chapter 3 ’Web Browser Interface’ — Interface Description
146 Amethyst III DTV Smart Switch
User Manual
PID 0x13 RST (3.7)
This test checks the Table Identifier (TID) of the sections
that are found on PID 0x13. The only TIDs that should be
found are 0x71 (RST) and 0x72 (ST).
There are no specific parameters to set.
M
TDT Interval (3.8.1)
This test checks the TDT periodicity, i.e. the intervals of
the TDT.
An alarm is raised if the interval between two
occurrences of the TDT is greater than the value set in
the Maximum period field, in milliseconds.
This test checks the first part of the test 3.8 TDT_error of
TR 101 290.
O
PID 0x14 TDT TOT (3.8.2)
This test checks the Table Identifier (TID) of the sections
that are found on PID 0x14. The only TIDs that should be
found are 0x70 (TDT), 0x73 (TOT) and 0x72 (ST).
There are no specific parameters to set.
This test checks the second part of the test 3.8 TDT_error
of TR 101 290.
M
Table 3-11. TR 101 290 Level 3 (DVB)
Format Persistence
Test Description
ASI
310M
GigE
Optional/Mandatory
Duration
Upper threshold
Lower threshold

Table of Contents

Other manuals for THOMSON Amethyst III

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the THOMSON Amethyst III and is the answer not in the manual?

THOMSON Amethyst III Specifications

General IconGeneral
BrandTHOMSON
ModelAmethyst III
CategorySwitch
LanguageEnglish

Related product manuals