Chapter 3 ’Web Browser Interface’ — Interface Description
174 Amethyst III DTV Smart Switch
User Manual
Tests Tab
The Tests tab provides a global overview of the quality of service of a
selected input. Alarms are sorted by TR 101 290 level and advanced level.
Figure 3-105. Tests view
Input
selector
Reset counters
button
Last counter
reset date
Input
state
TR 101 290 level
state
TR 101 290 test state
Alarm counter
Each TR 101 290 test line makes a synthesis of all alarms dealing with this
test.
For each test, a LED indicates the status. LEDs have the same meaning as
in the
rest of the GUI.
If the LED is gray , the corresponding test is disabled.
If the LED is green , the corresponding test is enabled, and there is
currently no corresponding alarm.
If the LED is red
, the corresponding test is enabled and there
is an error.
A counter indicates the number of alarms t
hat occurred on the selected
input since the last counter reset. The counter counts both active and
closed alarms. All alarms counters can be reset through the Reset
Counters button at the top right of the screen.