EasyManuals Logo

THOMSON Amethyst III User Manual

THOMSON Amethyst III
306 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #152 background imageLoading...
Page #152 background image
Chapter 3 ’Web Browser Interface’ — Interface Description
152 Amethyst III DTV Smart Switch
User Manual
Sub-Table Minimum
Interval on PID
This test checks that, for a given table, the sections
period are not lower than a given threshold.
You shall set exactly the same parameters than for the
maximum interval, described above.
O
Service Presence
This test checks that services that you configured are
referenced by the TS PAT.
For each service you wish to check, click the Add Service
ID button and specify the value in the displayed field.
NOTE: The list of services does not necessarily have to
be exhaustive: the test does not check that there is no
unexpected service.
Allowed PIDs
This test checks that there are not unexpected PID on the
TS.
For each PID you wish to check, click the Add PID button
and specify the PID value in the displayed field.
For this test, the exhaustive list of expected PIDs shall be
given.
The stuffing PID (0x1FFF) does not have to be given.
M
Scrambled PIDs
This test checks that the PIDs you configured are
scrambled.
For each PID you wish to check, click the Add PID button
and specify the PID value in the displayed field.
You can also check the Transport scrambling control
toggling box to check that the transport scrambling
control is effectively toggling periodically. Define in the
field the maximum cryptoperiod (in seconds) after
which an alarm should be raised if no change is
detected.
M
Not scrambled PIDs
This test checks that the PIDs you configured are not
scrambled.
For each PID you wish to check, click the Add PID button
and specify the PID value in the displayed field.
M
Continuity Counter
This test checks continuity counter of the PIDs you
configured.
For each PID you wish to check, click the Add PID button
and specify the PID value in the displayed field.
M
Table 3-14. Template checking tests
Format Persistence
Test Description
ASI
310M
GigE
Optional/Mandatory
Duration
Upper threshold
Lower threshold

Table of Contents

Other manuals for THOMSON Amethyst III

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the THOMSON Amethyst III and is the answer not in the manual?

THOMSON Amethyst III Specifications

General IconGeneral
BrandTHOMSON
ModelAmethyst III
CategorySwitch
LanguageEnglish

Related product manuals