OPUS Projektor Manual
Object Reference
Connect All Softkey Frames
When changing Softkey levels it is possible to switch a level of each Softkey Frame
separately or to connect all Softkey Frames. When the Softkey Frames are connected,
changing the level of one Softkey Frame will also change the level of the other.
Default value: Enabled
Possible values: Enabled or Disabled
Note: This property is only available for Page alarms. Frame alarms do not support
softkeys.
Timeout
The timeout of the alarm as configured in project properties for the alarm type.
This property can not be changed after the alarm was created.
Sound Pattern
When an alarm is created, the sound pattern as defined in the project properties is set for
the alarm. This sound pattern can be changed for each alarm individually.
For a detailed description of the sound pattern, refer to Alarms
Audio Output
When an alarm is created, the audio output options as defined in the project properties is
set for the alarm. This audio output configuration can be changed for each alarm
individually.
For a detailed description of the audio output configuration, refer to Events and Actions
Min Display Time
The minimal display time is the time that the alarm that the alarm is at least visible on the
screen. Only after this time the alarm can be acknowledged.
The value for the Min Display Time can only be set in the project properties for each
alarm type and can not be changed for each alarm.
Log this Alarm
When the alarm log is enabled in project properties , this property can be used to choose
if this particular alarm shall be logged or not.
Default value: Enabled
Possible values: Enabled or disabled.
If this property is enabled, it only has an effect if the alarm log is also enabled in project
properties.
Alarm Log Delay
With this property it can be configured if this alarm shall be logged directly when the alarm
is engaged or only after a certain amount of time. This can be helpful if an alarm shall only
be logged if it was engaged for a longer time.
Default value: 0 seconds (log this alarm directly without delay)
Possible values: 0 seconds to 2147483647 seconds
The value of this property only has an effect if Log this Alarm is enabled and the alarm log
is enabled in project properties .
Alarm Log Text
For this property a text can be entered that is used in the alarm log. This text can not be
automatically translated (it is not language dependent).
Default value: no value