OPUS Projektor Manual
Simulations
The value set in the simulation will be accepted by PClient
Please note that all value operations (manual and automatic) use the setting of this
checkbox when sending requests to the PClient.
Important note regarding the "Overwrite Owner's value" check box in combination with
internal variables owned by PClient: Predefined internal PClient variables have a
special action assigned (e.g. jumping to a page via @ProjectCurrentPage or managing
visibility with one of the visibility variables). If the check box for Overwrite Owners Value
for one of this variables is set, the action for this variable will not be executed. The
value is directly written to the variable bypassing the action.
If the PClient is configured to run using a CAN interface (see Simulation Settings ), this
checkbox is disabled (security reasons).
The checkbox "Only allow value changes by Simulation" will cause the PClient to
decline any variable value change requests that were not originated by the variable
simulation.
Use this checkbox for variables that are updated automatically and frequently by PClient so
that the value can be simulated and no conflicts arise.
Manual Value Change
There are several ways to change the value of a variable manually:
Min., Max. and default value
To quickly set minimum, maximum or the default value of the variable, the three buttons
·
Set to Default Value
·
Set to Min Value
·
Set to Max Value
can be used. The value that will be sent to the PClient is shown right beside the buttons.
Please note that Min. and Max. value operations are not available for string variables.
Manual value changes and incrementing
Below the "Manual Change (intended value)" label there are three ways to change the value
of the variable manually:
·
Just enter the value that shall be set in the manual value field and press enter or the
OK button right besides that field.
Note: The value in this field always shows the intended value and not neccessarily the
current value of the variable. Check the current value shown in the variable tree to
check if setting the value was successful.
·
Use the slider below the manual field to change the value between minimum and
maximum value of the selected variable
(not available for string variables)
·
Use the - or + button to decrement or increment the variable value. The amount of
decrement/increment can be set in the field between the -/+ button.
(not available for string variables)
Automatic Value Change
If the value of a variable shall be changed automatically, different value generators can be
configured for each variable.
To chose a generator use the drop down box below "Automatic Value Change".
The default for this is "Disabled".
596