8
© 2011 - 2015 TOSHIBA TEC CORPORATION All rights reserved e-STUDIO5540C/6540C/6550C/5560C/6560C/6570C
ERROR CODE and TROUBLESHOOTING
8 - 155
[CC80] Rear alignment motor abnormality
[CDE0] Rear alignment motor abnormality
Check item Measures
Hole punch control PC board (HP) • Download the latest version of the PNC board (HP)
firmware again and then check its operation.
• Connector check
• Board check
Replace parts Remarks
Hole punch control PC board
Classification Error item
Finisher related service call The rear alignment motor is not rotating or the rear alignment
plate is not moving normally. [MJ-1103/1104]
You receive a [CC80] error when the [ED14] error occurs
three times in succession.
Check item Measures
Rear alignment plate • Is there any mechanical problem when the rear alignment
plate is moved?
Rear alignment motor (M10) • Motor check
• Connector check
• Harness check
Finisher control PC board (FIN) • Connector check (CN17)
• Board check
Replace parts Remarks
Rear alignment motor
Finisher control PC board
Classification Error item
Finisher related service call The paddle motor is not rotating or the paddle is not rotating
normally. [MJ-1103/1104]
You receive a [CDE0] error when the [ED15] error occurs
three times in succession or during the initial operation.
Check item Measures
Paddle • Is there any mechanical problem with the paddle is
rotated?
Paddle motor (M8) • Motor check
• Connector check
• Harness check
Finisher control PC board (FIN) • Connector check (CN6)
• Board check
Replace parts Remarks
Paddle motor