Setting
RFID channels — overview of commands
Hans Turck GmbH & Co. KG | T +49 208 4952-0 | more@turck.com | www.turck.com
07.00 | 2022/09 | 162
Response
Read data, byte 5 HF:
EM4233 SLIC: 0
NXP SLIX2:
n Bit 0: Read protection, page 8
n Bit 1: Read protection, page 9
n Bit 2: Read protection, page 10
n Bit 3: Read protection, page 11
n Bit 4: Read protection, page 12
n Bit 5: Read protection, page 13
n Bit 6: Read protection, page 14
n Bit 7: Read protection, page 15
UHF: not required
Read data, byte 6 HF:
EM4233 SLIC: 0
NXP SLIX2:
n Bit 0: Read protection, page 16
n Bit 1: Read protection, page 17
n Bit 2: Read protection, page 18
n Bit 3: Read protection, page 19
n Bit 4: Reserved
n Bit 5: Reserved
n Bit 6: Reserved
n Bit 7: Reserved
UHF: not required
Read data, byte 7 0