Commissioning
Connecting the device to an EtherNet/IP scanner using RSLogix
Hans Turck GmbH & Co. KG | T +49 208 4952-0 | more@turck.com | www.turck.com
07.00 | 2022/09 | 69
RFID channels — process output data
Description Word offset Bit offset Bit length
Channel 0 Channel 1
Command code 0x0001 0x004D 0 16
Loop counter 0x0002 0x004E 0 8
Memory area (only UHF) 0x0002 0x004E 8 8
Start address 0x0003 0x004F 0 32
Length 0x0005 0x0051 0 16
Length UID/EPC 0x0006 0x0052 0 8
Read/write head address 0x000B 0x0057 0 8
Timeout 0x0007 0x0053 0 16
Read fragment No. 0x0008 0x0054 0 8
Write fragment No. 0x0008 0x0054 8 8
Write data Byte 0 0x000D 0x0059 0 8
Write data Byte 1 0x000D 0x0059 8 8
… … … … 8
Write data Byte 14 0x0014 0x0060 0 8
Write data Byte 15 0x0014 0x0060 8 8
… … … … 8
Write data Byte 64 0x002D 0x0079 0 8
Write data Byte 65 0x002D 0x0079 8 8
… … … … 8
Write data Byte 126 0x004C 0x0098 0 8
Write data Byte 127 0x004C 0x0098 8 8