Setting
RFID channels — parameter data
Hans Turck GmbH & Co. KG | T +49 208 4952-0 | more@turck.com | www.turck.com
07.00 | 2022/09 | 92
Manually addressing read/write heads — setting the HF read/write head address command
NOTE
Turck recommends making the bus address of the read/write head visible on the
device. The label on the cable can be used to mark the address on the read/write
head. The appropriate labels can be ordered with ID 6936206.
For information on addressing the read/write heads via the RFID interface with the Set HF read/
write head address command see page [}144]. With manual addressing via the Set HF read/
write head address command, the read/write heads must not be activated until the addressing
is completed.
NOTE
For manual addressing, only one read/write head may be connected to each RFID
channel at a time.
Activate the required read/write heads in the parameter data via the appropriate XCVR
bit.
HF RFID read/write head
e.g. TN-CK40-H1147/C53
RFID interface
TBEN-S2-2RFID-4DXP
RFID cable
e.g. RK4.5T-…-RS4.5T/S2500
Ethernet cable
e.g. RSSD-RJ45…
PC / Notebook
with Ethernet interface
Fig.74: Connecting the read/write head to a PC via the RFID interface