4-28 Adit 3000 (Rel. 1.6) and MSR Card (Rel 2.0) CLI
Global Configuration Mode
Global Configuration Commands
log
log lcc buffer
Use the log lcc buffer command to set the buffer size allowed for the Link Cross-Connect (LCC)
log buffer.
Syntax: (config)# log lcc buffer kilobytes
Example: (config)# log lcc buffer 24
Supported Platforms:
MSR
log lcc notify
Use the log lcc notify command to set the remote Link Cross-Connect (LCC) notify level.
Syntax: (config)# log lcc notify {error|info|ip-address address
|none|warn}
Example: (config)# log lcc notify warn
Supported Platforms:
MSR
Field Definition
kilobytes Set the size of the LCC log buffer. Range is 1 - 256 KB. Default is
16KB.
Field Definition
error Notify for error level.
info Notify for information level.
ip-address address Enter IP address of remote system to notify.
none No notification.
warn Notify for warning level.