Chapter 8 Operation 40058725 BTA Alpha HSM
Version: 12.19.17 Page 83 of 112 GB
Stop ramp
The stop ramp is set as a percentage of the ramp.
The explanations regarding the "Ramp" parameter
(Page 82) also apply for the "Stop ramp" and must
therefore be considered. The adjustment range is
10-200 %.
The display of the "Stop ramp" parameter in the configuration menu can be activat-
ed or deactivated by using the machine parameter 015 “StopRamp”. configuration" ma-
chine parameter in the system menu.
Speed control
The labeler speed and the product speed must be
identical in order to achieve optimal results.
This parameter specifies how the label speed is to
be controlled.
The setting "Internal" means that the label is ad-
vanced at the preset speed (comp. page80).
"Encoder" means that the label speed is continuously adapted to the products speed by
using an optional shaft encoder.
The display of the "Speed control" parameter in the configuration menu can be acti-
vated or deactivated via machine parameter 001 "Speed Int/Ext" in the system mode.
Sync Start
The Sync signal is provided at the I/O interface
(see page 48).
It normally starts with an incoming trigger signal.
The activation of the sync signal can only be de-
layed by the value set here in combination with
[Sync Length] (see Page 84). The adjustment
range is 0.0 – 900.0 mm.
The display of the "Sync Start" parameter in the configuration menu can be activat-
ed or deactivated with the 020 "Sync Conf" machine parameter in the system mode.