Chapter 9 Maintenance and repair 40058725 BTA Alpha HSM
Version: 12.19.17 Page 94 of 112 GB
Weekly repair/maintenance (after approx. 40 operating hours)
Prerequisites
Labeler is separated from the voltage and compressed air.
No product handling.
Tools required
Label remover (* 21800771)
Alcohol (* 21800915) or roller cleaner (* 21800977)
Lint-free cloth (* 21800978)
Compressed air spray (* 21800768)
Soft brush
* Product recommendation! Can be obtained from the Bluhm Weber Group using the 8-digit item number.
Instruction
How to perform the weekly maintenance/repair .
Clean all paper-carrying parts of adhesive deposits. To do this, use label
remover or alcohol.
Spray a cleaning cloth with label remover (alcohol) and wipe all surfaces
carefully with it.
Do not use the operational compressed air supply for the subsequent clean-
ings, since this is sometimes insufficiently dry (oil/water residues). If the
electronics come into contact with moisture, this will lead to damages!
Carefully clean all sensors (product sensor, label sensor...) with a soft brush
and compressed air spray.
Check movable assemblies such as the swivelable peeler plate etc. for
proper function (light running, freely movable, low bearing clearance...).
Check whether all the rollers will still move freely and that the axles of the
rollers are still firmly attached.