4-7
TRBL
SHTG
Troubleshooting
19 Battery voltage
malfunction
Below specified
voltage
C/E Engine does not restart (*1) Engine oper-
ates normally
unless it is
stopped
(*1) Depends
on battery con-
dition
1. Check the battery capacity
and specific gravity.
10-4
2. Check the fuse. 5-2
A-7
3. Check the battery cable and
terminals for proper connec-
tion.
—
4. Check the lighting coil output
peak voltage.
5-26
5. Measure the lighting coil
resistance.
5-26
6. Measure the Rectifier Regu-
lator output peak voltage.
5-26
7. Check the Rectifier Regula-
tor for continuity.
5-26
8. Check for wiring continuity
between the Rectifier Regu-
lator and fuse.
A-7
23 Intake temp sen-
sor malfunction
Out of specifica-
tion
C/E Higher idle speed
—
1. Check the air temperature
using the YDIS.
5-31
2. Measure the air temperature
sensor input voltage.
5-31
A-5
3. Measure the air temperature
sensor resistance.
5-31
4. Check for wiring continuity
between the air temperature
sensor and engine ECM.
5-31
A-5
Description of (*1) in the “Symptom” column is shown in the “Remarks.”
Trouble
code
Item Condition
Lan gauge
display
Symptom Remarks Checking steps
Refer to