8Alarm
DX100 8.3 Alarm Message List
8-527
4542 MRESET ERROR 1 An MRESET instruction was
executed while no endless axis
was designated.
Setting error (1)Check the following settings.
·Set the endless axis.
4543 STACK LESS
THAN 0(JOB
CALL)
At job return, an attempt was made
to fetch a data from an empty job
call stack or to stack a data in the
job call stack that is full.
Software operation
error occurred
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your Yaskawa representative about occurrence status
(operating procedure).
4544 MID$ INST ERROR 1 The first character of character
string to be extracted is null at
MID$ instruction execution.
Setting error (1)Check the following settings.
·Check the settings for the data of the character string to be extracted.
2 The extraction start position
exceeds the character string
length at MID$ instruction
execution.
Setting error (1)Check the following settings.
·Check the settings for the data of the character string to be extracted.
4546 CANNOT EXCUTE
SYSTEM JOB
Sub Code: System number Software operation
error occurred
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your Yaskawa representative about occurrence status
(operating procedure).
4547 PRIMITIVE
ERROR
Sub Code: Error code Software operation
error occurred
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your Yaskawa representative about occurrence status
(operating procedure).
4548 CANNOT
OPERATE
SPECIFIED
EVENT
Sub Code: System number Software operation
error occurred
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your Yaskawa representative about occurrence status
(operating procedure).
4549 NOT EXECUTION
OF INIEVNT
Sub Code: System number Setting error (1)Check the following settings.
·Execute an INIEVNT instruction before executing an event related
instruction.
Alarm
Number
Alarm Name Sub
Code
Meaning Cause Remedy