8Alarm
DX100 8.3 Alarm Message List
8-536
4594 SVHND CTRL
MODE CANCEL
ERR(SV)
Software operation
error occurred
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your Yaskawa representative about occurrence status
(operating procedure).
4595 CAN'T DO FIXED
FORM CUT
MOTION
1 The setting for radius is incorrect.
(1) For a circle, it is incorrectly set
as: radius ≤ 0, radius < minimum
radius value, or radius > maximum
radius value.
(2) For an ellipse, it is incorrectly
set as: radius ≤ 0, radius <
minimum radius value/2, or radius
> (maximum radius/2 - width/2).
Setting error (1)Check the following settings.
·Setting of the radius data
2 The setting for width is incorrect.
(1) For a rectangle, it is incorrectly
set as: width < 1.0, width > sqrt
(maximum diameter2 − height2),
or width > maximum diameter.
(2) It is incorrectly set as: width <
0, width > maximum diameter −2 *
radius.
Setting error (1)Check the following settings.
·Setting of the width data
3 The setting for height is incorrect.
(1) For a rectangle, it is incorrectly
set as: height > maximum
diameter, height < minimum
diameter/2, or height > sqrt
(maximum diameter
2
- width
2
).
Setting error (1)Check the following settings.
·Setting of the height data
4 The setting for the corner radius is
incorrect.
(1) For a rectangle, it is incorrectly
set as: corner radius > width/2 or
corner radius > height/2.
Setting error (1)Check the following settings.
·Setting of the corner radius
Alarm
Number
Alarm Name Sub
Code
Meaning Cause Remedy