8Alarm
DX100 8.3 Alarm Message List
8-542
4598 PAINTOUT
ERROR
1 The parameter setting for the
universal input group number is
incorrect.
Setting error (1)Check the following settings.
·Check the settings for the AxP011.
4599 SERVO
COMMAND
ERROR
An attempt was made to issue the
command while the servo control
processing has not completed.
Sub Code: Servo CPU bit number
Software operation
error occurred
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your Yaskawa representative about occurrence status
(operating procedure).
4603 WIRE STICKING Sub Code: Welder number Setting error (1)Check the following settings.
·Remove the cause of wire stick.
4604 SPECIFIED
ERR(ABSO
RECOVER AXIS)
Setting error (1)Check the following settings.
·Registration for the home position correction data.
4605 SETTOOL ERROR 1 The difference between the current
tool constant and a new set value
exceeded the allowable range
(parameter set value).
Setting error (1)Check the following settings.
·Correct the job so that the setting value of tag is allowable value.
·Set the allowance amount of the tool data automatic setting function
maximum deviation (S3C900) to large value.
4606 LACK OF GLOBAL
VARIABLE AREA
Software operation
error occurred
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your Yaskawa representative about occurrence status
(operating procedure).
4607 WRONG
EXECUTION OF
MACRO INST
1 The execution macro job is not set. Setting error (1)Check the following settings.
·Check the settings for execution macro job.
2 The interrupt macro job is not set. Setting error (1)Check the following settings.
·Check the settings for interrupt macro job.
3 An attempt was made to start the
job that could not be started by the
macro instruction.
Setting error (1)Check the following settings.
·Check the settings for macro job.
Alarm
Number
Alarm Name Sub
Code
Meaning Cause Remedy