10.3 Inspections and Guideline for Product Replacement Period
10.3.1 Inspections
10-24
10.3
Inspections and Guideline for Product Replacement Period
This section describes inspections and the product replacement period for the SERVOPACK.
10.3.1
Inspections
Perform the inspections given in the following table at least once every year for the SERVO-
PACK. Daily inspections are not required.
10.3.2
Guideline for Product Replacement Period
The electric and electronic parts in the SERVOPACK are subject to deterioration over time.
Replace the SERVOPACK using the following part service life as a guideline.
Item Frequency Inspection Correction
External
Appearance
At least once a
year
Check for dust, dirt, and oil on the
surfaces.
To clean the SERVOPACK, use
compressed air or another means
that will not create static electric-
ity.
Part
Guidelines for Part
Service Lives
Remarks
Electrolytic
Capacitor
5 years
The standard replacement periods given on the left are
for the following operating conditions.
• Surrounding air temperature: Annual average of 30°C
• Load ratio: 80% max.
• Operation rate: 20 hours/day max.