Table 735: Energizing inputs of SIM0002/SIM0904
Description Value
Current sensor input Rated current voltage (in
secondary side)
75 mV...9000 mV
1)
Continuous voltage
withstand
125 V
Input impedance at 50/60
Hz
2...3 MΩ
2)
Voltage sensor input Rated voltage
6 kV...30 kV
3)
Continuous voltage
withstand
50 V
Input impedance at 50/60
Hz
3 MΩ
1) Equals the current range of 40...4000 A with a 80 A, 3 mV/Hz Rogowski
2) Depending on the used nominal current (hardware gain)
3) This range is covered (up to 2*rated) with sensor division ratio of 10 000:1
Table 736: Binary inputs
Description Value
Operating range ±20% of the rated voltage
Rated voltage 24...250 V DC
Current drain 1.6...1.9 mA
Power consumption 31.0...570.0 mW
Threshold voltage 16...176 V DC
Reaction time 3 ms
Table 737: Signal output with high make and carry
Description
Value
1)
Rated voltage 250 V AC/DC
Continuous contact carry 5 A
Make and carry for 3.0 s 15 A
Make and carry for 0.5 s 30 A
Breaking capacity when the control-circuit time
constant L/R <40 ms
1 A/0.25 A/0.15 A
Minimum contact load 100 mA at 24 V AC/DC
1) X100: SO1
X110: SO1, SO2
X130: SO1, SO2 when REC615 is equipped with BIO0006