AutoTest Sytem Operation
Subject to Export Control, see Cover Page for details.
5-21
Set Commands (cont)
set_amfmmod_mod2_type [ 0 = Sine ]
Sets waveform shape for Modulator 3.
Default is 0 = Sine.
set_amfmmod_mod2_enable [ 0/1 ]
Turns modulation source for Modulator 3 ON/OFF.
Valid values are:
0 = OFF
1 = ON
set_amfmdemod_filter [ 0 - 7 ]
Sets demod filter.
Valid types are:
0 = None
1 = PSOPH
2 = 300 Hz
3 = 5 kHz
4 = 20 kHz
5 = 0.3 to 3.4 kHz
6 = 0.3 to 5 kHz
7 = 0.3 to 20 kHz
8 = 300 Hz HP
set_amfmdemod_psoph_filter [ type 0/1 ]
Sets psoph filter type.
Valid types are:
0 = CMESS
1 = CCITT
set_amfmdemod_fm_devtype [ type 0 /1 ]
Sets demod deviation type to RMS or peak.
Valid types are:
0 = Peak
1 = RMS
set_amfmdemod_freq_ulimit [ limit Hz ]
Sets upper limit for demod frequency measurements.
Format: Decimal limit value in Hz
set_amfmdemod_freq_ulen [ state 0/1 ]
Enables/Disables the upper limit check on demod frequency measurements.
Valid states are:
0 = Disabled
1 = Enabled
set_amfmdemod_freq_llimit [ limit Hz ]
Sets lower limit for demod frequency measurements.
Format: Decimal limit value in Hz