AutoTest Sytem Operation
Subject to Export Control, see Cover Page for details.
5-27
Set Commands (cont)
set_analyzer_startfreq [ freq MHz ]
Sets analyzer Start frequency when in Start - Stop mode.
Format: Decimal value in MHz
set_analyzer_stopfreq [ freq MHz ]
Sets analyzer Stop frequency when in Start - Stop mode.
Format: Decimal value in MHz
set_analyzer_centerrel [ freq MHz ]
Sets Center frequency relative to analyzer.
Format: Decimal value in MHz
set_analyzer_startrel [ freq MHz ]
Sets Start frequency relative to analyzer.
Format: Decimal value in MHz
set_analyzer_stoprel [ freq MHz ]
Sets Stop frequency relative to analyzer.
Format: Decimal value in MHz
set_analyzer_mode [ state 0/1 ]
Sets analyzer span mode.
Valid states are:
0 = Channel
1 = Full
Must include a 10 s wait command after this command.
set_analyzer_source [ state 0/1 ]
Selects analyzer trace source.
Valid states are:
0 = T/R
1 = ANT
set_analyzer_preamp_enable [ state 0/1 ]
Enables/Disables Pre-Amp feature.
Valid states are:
0 = Disabled
1 = Enabled
set_analyzer_marker1enable [ state 0/1 ]
Enables/Disables Marker at set position.
Valid states are:
0 = Disabled
1 = Enabled
set_analyzer_marker1position [ value in MHz ]
Sets marker position.
Format: Decimal value in MHz