EasyManuals Logo

Agilent Technologies 93000 SOC Series User Manual

Agilent Technologies 93000 SOC Series
632 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #423 background imageLoading...
Page #423 background image
Lesson 1 Test Method Structure
423
Special operations like A-law and u-law encoding/decoding for
CODEC devices.
To compute the test result from the raw measurement data, you
can use the Computation APIs.
Judgement API
To make a judgement (pass or fail) on a test, use the following API:
TEST (pin, testname, result_value, continue_if_fails);
This function takes a value representing the final result of the test,
then returns the Pass to the test flow if the variable is within the
limit range. The limit range is provided to the test method
program from your entry in the Parameter dialog for the present
test method. Here, the system software uses the testname
identifier. The testname, which was specified in the Parameter
and Limit Table dialog of the Test Method Editor, will be used as
the identifier.
The parameter dialog opened from the testsuite dialog of the Test
Flow Editor is the dialog box where you can enter limit values for
each "testname" before execution. For more information on these
topics, see Lesson 2 in this unit.
testname Identifier and Related Dialogs
By default, the program execution will be terminated if the TEST
API failed. Instead, you can continue executing the program after
the TEST API if you set the option to TRUE as follows:

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Agilent Technologies 93000 SOC Series and is the answer not in the manual?

Agilent Technologies 93000 SOC Series Specifications

General IconGeneral
BrandAgilent Technologies
Model93000 SOC Series
CategoryTest Equipment
LanguageEnglish

Related product manuals