EasyManuals Logo

Agilent Technologies 93000 SOC Series User Manual

Agilent Technologies 93000 SOC Series
632 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #501 background imageLoading...
Page #501 background image
Lesson 3 – TIA Test Method Programming and Test Execution
501
3-2 TIA API Functions
This lesson describes how to use the basic API commands that
build a test method for a TIA Test.
Setting the Primary Routing Set
Unlike the other primary sets, the primary routing set is not
defined in the test suite. It must be defined in the test method.
The primary routing contains the routing definitions to be used
during the TIA test.
The following command defines the primary routing set:
Setting the Primary Routing Set
Enabling the Input Channels and Trigger Line of the
TIA
By default, the input channels and the trigger line of the TIA are
disabled to prevent the TIA from starting its operation due to
unintended input such as noise.
Therefore, the input channels and the trigger must be enabled
before the test execution. This is done with the command:
Enabling the Input Channels and the Trigger Line of the TIA

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Agilent Technologies 93000 SOC Series and is the answer not in the manual?

Agilent Technologies 93000 SOC Series Specifications

General IconGeneral
BrandAgilent Technologies
Model93000 SOC Series
CategoryTest Equipment
LanguageEnglish

Related product manuals