28 — I-211M-K and I-211M-L unit data sheet
Alcatel-Lucent 7302 ISAM | 7330 ISAM FTTN | 7360 ISAM FX ONT R04.06.02 November 2013 28-9
3FE 55873 AAAA TCZZA Edition 01
ONT Product Information Guide
Table 28-8 Physical specifications for the I-211M-L ONT within a Just Inside enclosure
Table 28-9 lists power consumption specifications for I-211M-K and I-211M-L
indoor ONTs.
Table 28-9 I-211M-K and I-211M-L indoor ONT power consumption specifications
Table 28-10 lists the environmental requirements for I-211M-K and I-211M-L
indoor ONTs.
Table 28-10 I-211M-K and I-211M-L indoor ONT environmental requirements
Dimensions Specification
Height 18.3 in. (46.4 cm)
Width 12.0 in. (30.5 cm)
Depth (including cable storage tray) 4.3 in. (10.9 cm)
Weight [within ± 0.5 lb (0.23 kg)] 7.5 lb (3.4 kg) without battery
Mnemonic Maximum power
(not to exceed)
Condition Minimum power Condition
I-211M-K 10.5 W 2 POTS off-hook, 1 Gig-E,
MoCA and Video operational
7 W 2 POTS on-hook, other
interfaces/services not
provisioned
I-211M-L 10.5 W 2 POTS off-hook, 1 Gig-E,
MoCA and Video operational
7 W 2 POTS on-hook, other
interfaces/services not
provisioned
ONT type
Mounting method Temperature range and humidity Altitude
I-211M-K indoor MoCA ONT
Desk or wall
mounted
Operating:
32°F to 104°F (0°C to 40°C) without solar loading
5% to 95% relative humidity, non-condensing
Maximum operating altitude is 10 000
ft (3048 m) above mean sea level
Storage:
32°F to 104°F (0°C to 40°C)
5% to 95% relative humidity, non-condensing
Maximum non-operating altitude is
40 000 ft (12 192 m) above mean sea
level
Indoor MoCA ONT (I-211M-L indoor desktop)
Desk or wall
mounted
Operating:
AA and AB variant -40°F to 149°F (-40°C to 65°C)
5% to 95% relative humidity, non-condensing
Maximum operating altitude is 10 000
ft (3048 m) above mean sea level
Storage:
AA and AB variant: 32°F to 104°F (0°C to 40°C)
5% to 95% relative humidity, non-condensing
Maximum non-operating altitude is
40 000 ft (12 192 m) above mean sea
level