EasyManua.ls Logo

Alcatel-Lucent 7360 - SLID Settings

Alcatel-Lucent 7360
1073 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6 — ONT management using an ONT interface
6-56 November 2013 Alcatel-Lucent 7302 ISAM | 7330 ISAM FTTN | 7360 ISAM FX ONT R04.06.02
Edition 01 3FE 55873 AAAA TCZZA
ONT Product Information Guide
Table 6-11 SLID settings
This section shows you how to:
view or retrieve the current SLID setting
clear (reset) the SLID
enter or modify a SLID
Prerequisites
The prerequisites are:
To enter a SLID, the user access level of the ONT is read-write.
To view current SLID settings, the user access level of the ONT is read only, or
read-write.
The ONT must have a SLID value of null or default before you can enter a new
SLID. To reset a SLID to its default value, you must clear it.
The steps to access the interface are completed.
See Procedure 6-1 for HTTP interface using the first Ethernet port.
See Procedure 6-3 for CLI interface using the craft port.
See Procedure 6-6 for HTTP interface for Package C ONTs.
See Procedure 6-7 for Package C ONT CLI interface using the craft port.
See Procedure 6-8 for Package C ONT CLI interface using an Ethernet port.
Parameter Value Description
Mode Volatile In volatile mode:
The SLID at the ONT returns to its default value
after the ONT is powered off and on.
The SLID is delivered to the P-OLT in the
proprietary mode, which uses the proprietary
PLOAM message.
Permanent In permanent mode:
The SLID at the ONT retains its configured value
after the ONT is powered off and on.
The SLID is delivered to the P-OLT in the
proprietary mode, which uses the proprietary
PLOAM message.
Registration In registration mode:
The SLID at the ONT retains its configured value
after the ONT is powered off and on.
The SLID is delivered to the P-OLT in registration
ID mode, which uses the password PLOAM message
defined in G.984.3.
String format Hexadecimal Hexadecimal string of 0 to 9 and usually a to f or A to
F, with zeroes appended to a length of 20 characters
Alphanumeric String of up to 10 characters (default)
SLID value DEFAULT The ONT is set to a default value.
Non-default value

Table of Contents

Related product manuals