6 — ONT management using an ONT interface
6-60 November 2013 Alcatel-Lucent 7302 ISAM | 7330 ISAM FTTN | 7360 ISAM FX ONT R04.06.02
Edition 01 3FE 55873 AAAA TCZZA
ONT Product Information Guide
9 Perform one of the following to provision ONT and services:
a If the ONT and services were preprovisioned at the P-OLT, the P-OLT will
automatically range and provision the ONT, after the ONT is connected to the
PON optical cable.
b If the ONT and services were not pre-provisioned at the P-OLT, notify the TL1
or network manager GUI operator to provision the ONT and services at the
P-OLT using SLID.
10 STOP. This procedure is complete.
Procedures using CLI interface
The following procedures provide the steps to view the current SLID settings, to
clear the SLID, and to enter the SLID using the CLI interface.
Procedure 6-41 To view current SLID settings
1 Choose option 4, Retrieve SLID, from the Main menu.
The system displays the string format, the mode, and the value of the SLID.
Example:
The SLID in ALPHANUMERIC MODE (Volatile) : DEFAULT
where the SLID settings are described in Table 6-11
2 STOP. This procedure is complete.
Note — To enter or clear a slid:
• If you are using an Ethernet connection, the ONT must be
disconnected from the PON optical cable.
• If you are using a craft connection, the ONT can be connected or
disconnected from the PON optical cable. However, if you
configure the SLID with the ONT connected to the PON optical
cable, the data at the ONT is not changed; the data at the ONT is
only changed after the ONT reranges. Rerange the ONT by
disconnecting and reconnecting the PON optical cable, which
generates a NEWONT alarm.