EasyManua.ls Logo

Alcatel-Lucent 7360 - Business ONT Physical Specifications (B-0404 G-B); B-0404 G-B Business ONT Power Consumption Specifications; B-0404 G-B GEM Ports and T-Conts

Alcatel-Lucent 7360
1073 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
9 — B-0404G-B unit data sheet
9-6 November 2013 Alcatel-Lucent 7302 ISAM | 7330 ISAM FTTN | 7360 ISAM FX ONT R04.06.02
Edition 01 3FE 55873 AAAA TCZZA
ONT Product Information Guide
Table 9-6 Business ONT physical specifications (B-0404G-B)
Table 9-7 lists the power consumption specifications for B-0404G-B business ONTs.
Table 9-7 B-0404G-B business ONT power consumption specifications
Table 9-8 lists the environmental specifications for B-0404G-B business ONTs.
Table 9-8 B-0404G-B business ONT environmental specifications
9.7 B-0404G-B GEM ports and T-CONTs
Table 9-9 lists the maximum number of supported T-CONTs and GEM ports. See the
appropriate release Customer Release Notes for the most accurate list of supported
devices.
Table 9-9 B-0404G-B business ONT capacity for GEM ports and T-CONTs
Dimensions Specifications
Length 8.2 in. (20.83 cm)
Width 5.6 in. (14.24 cm)
Height 1.3 in. (3.3 cm)
Weight [within ± 0.5 lb (0.23 kg)] 0.97 lb (0.44 kg) production weight
Mnemonic Maximum power
(Not to exceed)
Condition Minimum power Condition
B-0404G-B 9 W 4 Gig-E, 4 DS1 operational 6 W All interfaces inactive
Mounting method Temperature range and humidity Altitude
B-0404G-B on desk
or wall mounted
Operating:
-4°F to 122°F (-20°C to 50°C)
5% to 93% relative humidity, non-condensing
Maximum operating altitude is 10 000 ft (3048
m) above mean sea level
Maximum non-operating altitude is 40 000 ft
(12 192 m) above mean sea level
Storage: Contact your Alcatel-Lucent support
representative for more information
ONT or MDU Release Maximum Notes
Package L ONTs
GEM ports per ONT ONT R2.0 64
ONT R2.1.x, ONT R2.2 256
(1 of 2)

Table of Contents