NTP 148 — Install an I-040G-R indoor ONT
NTP 148-2 November 2013 Alcatel-Lucent 7302 ISAM | 7330 ISAM FTTN | 7360 ISAM FX ONT R04.06.02
Edition 01 3FE 55873 AAAA TCZZA
ONT Product Information Guide
Safety information
Read the following safety information before installing the unit.
Procedure
Use this procedure to install an I-040G-R indoor ONT.
1 Prepare the cables at the site where the ONT will be installed (DLP 100). Also,
locate the power source where the power converter will be installed.
2 Are any of the cables missing?
a If yes, go to step 3.
b If no, go to step 4.
3 Locate each missing cable and route them to the ONT as per local practices.
Danger 1 — Contact the local utility company before you connect the
enclosure to the utilities.
Danger 2 — Observe the local and national laws and regulations that
may be applicable to this installation.
Warning — This equipment is ESD sensitive. Proper ESD protections
should be used when handling the indoor ONT.
Caution — Keep indoor ONTs out of direct sunlight. Prolonged
exposure to direct sunlight can damage the unit.
Note — Observe the following:
The indoor ONT should be installed in accordance with the
applicable requirements of the NEC or CEC. Local authorities and
practices take precedence when there is conflict between the local
standard and the NEC or CEC.
The indoor ONT must be installed by qualified service personnel.
Indoor ONTs must be installed with cables that are suitably rated
and listed for indoor use.
See “I-040G-R unit data sheet” in the unit data sheet for the
temperature ranges for these ONTs.