NTP 152 — Replace an I-110G-P indoor ONT
Alcatel-Lucent 7302 ISAM | 7330 ISAM FTTN | 7360 ISAM FX ONT R04.06.02 November 2013 NTP 152-3
3FE 55873 AAAA TCZZA Edition 01
ONT Product Information Guide
Figure NTP 152-1: I-110G-P indoor ONT connections
3 Replace the ONT with a new unit:
a On a flat surface, such as a desk, substitute a replacement ONT for the old
ONT; go to step 5.
b On a wall.
i Slide the old ONT off of the mounting screws until the ONT is free of the
wall.
ii Install the replacement ONT following the wall mounting instructions
for an I-110G-P indoor ONT (DLP 122).
4 Connect the POTS cables to the RJ-11 ports (DLP 123).
5 Connect the Ethernet cable to the RJ-45 port (DLP 101).
6 If required, have approved service personnel who are trained to work with optic
fiber clean the fiber optic connection. See DLP 134 for more information about
fiber optic handling, inspection, and cleaning.
7 Connect the SC/APC fiber optic cable (DLP 125).
8 Install the power supply according to manufacturer specifications.
Danger — Fiber optic cables transmit invisible laser light. To avoid eye
damage or blindness, never look directly into fibers, connectors, or
adapters.
Warning — Be careful to maintain a bend radius of no less than 1.5
inches (3.8 cm) when connecting the fiber optic cable. Too small of a
bend radius in the cable can result in damage to the optic fiber.
Note — Observe the following:
• Units must be powered by a Listed or CE approved and marked
limited power source power supply with a minimum output rate of
12 V dc, 1.25 A.
GE3
GE4
21546
PWR
POWE
R
GPON
ETHERNET
UPDATE
POTS
SC/APC
connector
POTS
port RJ-11
Ethernet (GE)
port RJ-45
Power
connector