NTP 118 — Install an I-010G-A indoor ONT
NTP 118-6 November 2013 Alcatel-Lucent 7302 ISAM | 7330 ISAM FTTN | 7360 ISAM FX ONT R04.06.02
Edition 01 3FE 55873 AAAA TCZZA
ONT Product Information Guide
Figure NTP 118-5: I-010G-A indoor ONT with cabling
10 Connect the SC/APC fiber optic cable (DLP 125); see Figure NTP 118-5.
11 If used, configure the SLID (DLP 129).
12 Verify the ONT LEDs.
13 Activate and test the services (DLP 128).
14 STOP. This procedure is complete.
Danger — Fiber optic cables transmit invisible laser light. To avoid eye
damage or blindness, never look directly into fibers, connectors, or
adapters.
Warning — Be careful to maintain a bend radius of no less than 1.5
inches (3.8 cm) when connecting the fiber optic cable. Too small of a
bend radius in the cable can result in damage to the optic fiber.
19836
Power
connector
Ethernet (GE)
RJ-45
SC/APC
connector