10 — B-2404-P unit data sheet
10-6 November 2013 Alcatel-Lucent 7302 ISAM | 7330 ISAM FTTN | 7360 ISAM FX ONT R04.06.02
Edition 01 3FE 55873 AAAA TCZZA
ONT Product Information Guide
Table 10-5 B-2404-P business ONT LED descriptions
10.6 B-2404-P detailed specifications
Table 10-6 lists the B-2404-P business ONT physical specifications.
Table 10-6 B-2404-P business ONT physical specifications
Indicator Color Description
PWR Green solid
Green flashing slow
Green flashing fast
Red solid
Operating from AC power
Operating from battery power
System booting
Battery low
GPON Off
Green solid
Green flashing slow
Red solid
07
Optical OK; Ranged
PON is in ranging and synchronizing process
Optical Power Off (LOS/LOF)
DATA Off
Green solid
Green flash
Ethernet service is not configured in ONT
Ethernet service is configured in ONT
Ethernet service is configured and there is activity of receiving or
transmitting data
CES Off
Green solid
Green flashing
CES data path is not setup
CES data path is ready
LED blinks when links are up and there is activity (data receive and
transfer). LED blinks with a 167 ms cycle and 50% duty cycle.
TIMING Off
Green solid
Green flashing
Reference clock is not valid
Reference clock ready
In holdover state
UPDATE Off
Green flashing fast
Red solid
Normal status
Upgrading
Upgrade failure
ALARM Off
Green solid
Red solid
Normal status
No alarm with local Ethernet access enabled (for Telnet)
Indicates hardware failure
POTS Off
Green solid
Green flashing fast
Telephone at POTS A and B are all in the onhook condition
Telephone at POTS A and B are all in the offhook condition
At least one POTS is in offhook condition for at least one hour
TEST Off
Green solid
Green flashing fast
Normal status
ONT is under loopback test
ONT is in normal state with local Ethernet access (for Telnet) enabled
Description Specification
Length 7.87 in. (20 cm)
Width 10.51 in. (26.7 cm)
(1 of 2)