6 — ONT management using an ONT interface
6-16 November 2013 Alcatel-Lucent 7302 ISAM | 7330 ISAM FTTN | 7360 ISAM FX ONT R04.06.02
Edition 01 3FE 55873 AAAA TCZZA
ONT Product Information Guide
Procedures using CLI interface for Package C ONTs
The CLI interface for Package C ONTs is accessible in two ways:
• craft port—The CLI interface is accessible through a craft port, which is provided
by some ONT models. You connect to the craft port with an RS-232 DB-9
connector, using a VT100 terminal or PC terminal emulation software set at 9600
Baud, 8 bits, no parity.
• Ethernet over LAN—The CLI interface is accessible through an Ethernet port on
an ONT using a computer or laptop with Telnet software.
The following procedures provide the steps to access and to disconnect from the CLI
interface using a craft port, or an Ethernet port.
Procedure 6-7 To access the CLI interface using a craft port
1 Connect a laptop via serial cable to the RS-232 connector on the ONT.
2 Configure the communications software to the following settings:
• bits/second = 9600
• data bits = 8
• parity = None (N)
• stop bits = 1
• terminal emulation = VT100
3 Log in to a craft session:
<L>ogin
User Name:CRAFTSPERSON
Password:ALC#FGU
where
User Name is the username for the ONT
Password is the password for the ONT
The SLID menu appears.
4 STOP. This procedure is complete.
Procedure 6-8 To access the CLI interface using an Ethernet port
1 Connect a computer or laptop to an Ethernet port on the ONT using an Ethernet
cable.
2 Press the Reset button on the ONT. The ONT reboots with an enabled Telnet
server.
3 Start a Telnet session and Telnet to the ONT at 192.168.1.251.