22 — I-020E-B, I-020E-H, and I-020G-F unit data sheet
Alcatel-Lucent 7302 ISAM | 7330 ISAM FTTN | 7360 ISAM FX ONT R04.06.02 November 2013 22-11
3FE 55873 AAAA TCZZA Edition 01
ONT Product Information Guide
I-020E-B, I-020E-H, I-020G-F ONT considerations and limitations
Table 22-13 lists the considerations and limitations for these ONTs.
Table 22-13 I-020E-B, I-020E-H, I-020G-FONT considerations and limitations
I-020E-B and I-020E-H ONT hardware limitations
Table 22-14 lists the hardware limitations for I-020E-B and I-020E-H indoor ONTs
when configuring services.
Table 22-14 I-020E-B and I-020E-H indoor ONT hardware limitations
Note
(1)
See Operations and Maintenance documentation for the I-020E-B or I-020E-H for information on
these parameters.
Considerations and limitations
No support for per VLAN protocol downstream tagging mode
In SVLAN cross-connect tunnel mode:
use non-overlapping pbits since the use of the same pbits on two or more VLAN ports results in
a mismatch alarm
downstream frames sent with a single tag normally sent out on the user-side as untagged, will
instead be sent as priority tagged
When using CVLAN translation, or when the same queue is used for multiple pbits, the highest pbit
value in the queue in the downstream direction will be selected to stomp the pbit in the packet
Simultaneous configuration of a CVLAN port and an S-Tunnel on the same UNI will only be supported
if these services are provisioned with non-overlapping pbits
The same VLAN port must be used when employing both protocol-based VLAN for PPPoE and
IPoE-based VLANs
When the VLAN is translated, the pbit value must be modified and the highest pbit value is mapped
to that GEM port
When more than one Ethernet port is in VLAN translation mode, or set to flexible mode with IGMP
channels created, the USERSIDE VLAN IDs of those services are different. All downstream multicast
packets will be tagged on the UNI port with VLAN ID of 4094
Maximum use of multicast on 1 Ethernet port at a time
For C forwarder and S+C CC forwarder, if the VLAN port uses regenerated profiles or regenerated
pbits, then the downstream traffic can only flow with the derived pbits
When either tip or ring is grounded, DGNONTPOTS tip to ground and ring to ground restrictive
measurements are simultaneously reported as 0 ohms
Limitation Parameters
(1)
Service (s)
For I-020E-B and I-020E-H ONTs the link will come up in half
duplex when the link partner is manually configured to 10
or 100 Mb/s, if you configure the ONT for AUTOFD. All other
ONTs will not link up in this situation. The TL1 command
REPT-OPSTAT-ONTENET will indicate the link status.
autodetect ONT
Ethernet
port